Advance Dynamic Alternating Mattress

Advance Dynamic Alternating Mattress

Certificates

The MT 07 air cells dynamic mattress replacement system provides effective therapy with reliable high quality TPU coated air cells for pressure ulcer prevention. The 20 cm height 20 air cells with full 10 cm height immersion mattress replacement with our digital pumps is ideal for patients at medium to very high risk of pressure ulcer development.

The MT 07 features 20 dynamic alternating air cells with 2-1 Alternating and 3 static head cells. The 20 cell-on-cell design provides better support and more comfortable experience. In the event of power outage, the cell-on-cell design can also support the patient.

The MT 07 is an advanced multi-functional microcontroller programmed 9.0L+9.0L dual linear compressors digital pump with a detachable power cord dynamic mattress replacement system. The high flow rate fast inflation dual compressors digital pump has a precise digital pressure transducer which is able to reduce the power wattage once the pressure is reached therefore it is the most quiet, power efficiency, and extended lifetime pump. The digital pump has 20 minutes static mode, alternate mode with selectable cycle time, Constant Low Pressure (CLP) or pulsate mode with selectable cycle time, auto-firm mode, and auto-detection mode. To insure patient’s safety, the pump has audio visual low pressure, power failure, and service alarms with error code.

Technical Parameters

 Mattress  8″ Replacement
 Dimension (cm)  200x90x20
 Number of Cells  20
 Cell Material  TPU
 Top Cover Material  Two-Way Stretch Polyester
 Pillow Section  Yes, 3 Cells
 Cell-on-Cell Design  Yes
 Independent Low Air Loss (iLAL)  Yes (Up to 75L per Cycle)
 CPR Type  AKTC Q-CPR
 Recommendation Maximum Weight (kg)  255
 Warranty  1 Year
 –  –
 Pump  Digital
 Dimension (cm)  43x13x24
 Supply Voltage  230V/50Hz
 Alternating Type  2-1 Alternating
 Flowrate (Liter)*  9.0 + 9.0
 Control Panel Type  Digital Keypad + Seven-Segments LED Display
 Mode  Alternate, Static, Constant Low Pressure (CLP)
 Full Cycle Time (Minutes)  Selectable 10, 15, 20, 25, 30
 Alarms  Audiovisual Alarms (Power Failure, Low Pressure, and Service Alarm with Error Code)
 Auto Pressure Detection  Yes
 Power Code Type  Detachable
 Classification  Class II, Type BF
 Electrical Safety Standards  IEC60601-1,
IEC60601-1-2,
IEC60601-1-11 Homecare Standard
 Warranty  1 year

* The flow rate may be varied due to fluctuation of input voltage